The Articulator CA 3.0 excels through its simple handling and precision. It was designed along the camper plane. It runs parallel to the occlusion plane, thus giving an unambiguous and practical reference for daily work.
The temporomandibular joint is both a rotating and sliding joint with two types of movement: the rotation or hinged axis as well as the translational or sliding movement. The most common form of movement is a combination of both types of movement. A rotation with simultaneous translation – a rotary sliding. Interaction between the two temporomandibular joints allows rotational movement along axes other than the hinged axis. Three axes of movement can be determined.
The shape of the natural joint head is copied and simulated by the double cone in the Articulator CA 3.0. This avoids unphysiological, straight movement patterns in lateral and transverse motion sequences.
The CA 3.0 is equipped with two guide edges that guide the double cone.
A vertical-sagittal one on the retrusion bar (red) and a horizontal-sagittal one on the joint disk (green).
The vertical-sagittal edge on the retrusion bar touches the inner cone (red) whereas the horizontal-sagittal edge guides along the apex of the double cone (green).
As a result, with lateral movements, the double cone is not only guided into a physiological, three-dimensional movement via the horizontal guide edge of the joint disk (green), but also via the vertical guide edge on the retrusion bar (red).
The condyle moving on the non-working side is the mediotrusion condyle: during a lateral movement (mediotrusion) the moving condyle moves forward in a downward direction.
The condyle resting on the working side is the laterotrusion condyle: this side is used for chewing and the teeth are in occlusion. This condyle can rotate around the vertical axis and also move laterally.
The CA 3.0 allows virtually identical natural 3D simulation of the lateral and Bennett movement. Functional hyper-contacts are avoided.
Handy, light-weight, and robust aluminum construction. This design facilitates simple, physiological operation procedures. Heavily stressed elements such as the joint and vertical pin are made of stainless steel. The incisal plate is made of durable POM acrylic.
1 Incisal pointer CA 3.0
2 Retention discs
3 Plastic mounting plates
4 Metal mounting plates
5 Incisal guide standard CA 3.0
6 Vertical guide rod CA 3.0
7 Vertical guide rod holder CA 3.0
8 Supporting rod for opening stop
9 O-ring seals
10 Knurled thumb screw A
11 Knurled thumb screw B
A direct transfer of other brands (facebow) into the CANDULOR Articulator CA 3.0 is possible with the facebow adapter.
Facebow adapter L/R for:
Exact details are given in the instructions for use.
Weight | N/A |
---|---|
Dimensions | N/A |
Options | Articulator CA 3.0 Instrument Holder w/Flat Setup Template, Articulator CA 3.0 Flat Setup Template, Articulator CA 3.0 Universal Facebow Adaptor, Articulator CA 3.0 Facebow Mount, Articulator CA 3.0 Spare Part Incisal Guide 15” Standard, Articulator CA 3.0 Spare Part Incisal Pointer, Articulator CA 3.0 Spare Part Plastic Mounting Plates, Articulator CA 3.0 Spare Part Metal Mounting Plates, Articulator CA 3.0 Spare Part Retention Disks, Articulator CA 3.0 Spare Part Plastering Covers, Articulator CA 3.0 Spare Part Labels, Articulator CA 3.0 Spare Part O-Ring Seals, Articulator CA 3.0 Spare Part Vertical Guide Rod, Articulator CA 3.0 Spare Part Vertical Guide Rod Holder, Articulator CA 3.0 Spare Part Knurled Thumb Screw A, Articulator CA 3.0 Spare Part Knurled Thumb Screw B, Articulator CA 3.0 Spare Part Supporting Rod for Opening Stop |